Abstract

 PT. PLN Nusantara Power UP Tenayan is a company operating in the power generation sector and focuses on operating PLTUs Tenayan, Indonesia. One part of the machine that influences the operation of the generator is the boiler feed pump. Lack of optimal boiler feed pump instrumentation often results in failure in operating activities. This research uses the Failure Mode and Effect Analysis (FMEA) method with the research objective of finding out the causes of failures that occur, identifying the type of failure, and determining the RPN value and the impact that occurs. The analysis results, it shows that the Boiler Feed Pump instrumentation components still meet operating standards because the Risk Priority Number (RPN) value is below 200, even though the Speed Sensor has a fairly high RPN value but is still in the reliable category, the result of identifying the type of failure that occurs is that the indicator reading is not actual, the component is not functioning, the highest RPN value for the Boiler Feed Pump component is the Speed Sensor component with an RPN value of 160 and the lowest RPN value is for the pressure indicator component with an RPN value of 30. The most important recommended action for the Speed Sensor component is to carry out maintenance for 1 month very.

Keywords – Boiler Feed Pump, FMEA, Keandalan, Pembangkit, RPN.

Author Biographies

  • Raehan Adillah S, Universitas Islam Negeri Sultan Syarif Kasim Riau
    Program studi Teknik Elektro, Fakultas Sains dan Teknologi
  • Jufrizel Jufrizel, Universitas Islam Negeri Sultan Syarif Kasim Riau
    Program studi Teknik Elektro, Fakultas Sains dan Teknologi
  • Putut Son Maria, Universitas Islam Negeri Sultan Syarif Kasim Riau
    Program studi Teknik Elektro, Fakultas Sains dan Teknologi
  • Hilman Zarory, Universitas Islam Negeri Sultan Syarif Kasim Riau
    Program studi Teknik Elektro, Fakultas Sains dan Teknologi

References

L.Apriliasa, and D. Ichsani, “Desain Compact heat exchanger Tipe Fin and tube Sebagai Alat Pendingin Motor pada Boiler Feed Pump (Studi Kasus pada Sebuah Perusahaan Pembangkit Tenaga Listrik)â€, Jurnal Teknik Pomtis Vol. 2, No. 2. 2017

I. Gunawan, H. Eteruddin, and U. Situmeang, “Analisis Transien Pada Sistem Transmisi 150KV Riau Setelah Beroperasinya PLTU Tenayan Raya Menggunakan Power World Simulatorâ€, Jurnal Teknik, Vol. 14, 223-231. Oktober. 2020.

N. Hendri, ''Live Streamins : PLN Ungkap Riau Masih Kekurangan Daya Listrik 270 MW'. Tribunpekanbaru.com, Pekanbaru, maret. 2018.

Badan Pusat Statistik Provinsi Riau, “Jumlah Penduduk Menurut Kabupaten / Kota di Provinsi Riau, 2010-2019â€, 2020.

Y. A. Prasetyo, Japri, Sunaryo, “Penerapan Reliability Centered Maintenance Pada Peralatan Ship Unloader PLTU Tenayan 2 X 110 MW’, Jurnal Teknik Industri Terintegrasi (JUTIN), Vol. 3, No. 2. November. 2020.

R. A. Pratomo, “Analisis Penurunan Performa Pada Boiler Feed Pump Sebagai Langkah Reactive Maintenance di PJB UP Gresikâ€, Skripsi, IT SEPULUH NOPEMBER SURABAYA. 2018.

W. O. Widyarto, G. A. Dwiputra, Y. Kristiantoro, “Penerapan Konsep Failure Mode and Effect Analysis (FMEA) Dalam Pengendalian Kualitas Produk Dengan Menggunakan Metode Six Sigmaâ€, Jurnal REKAVASI, Vol. 3, 54-60. 2015.

F. Noviardi, “Analisa Keandalan Sistem Instrumentasi Pada Rotary Machine Di PT. Asia Forestama Raya dengan Menggunakan Metode Failure Mode and Effect Analysisâ€, Skripsi, UIN SUSKA RIAU. 2020.

A. Faizal, S. Arifin, “Analisis Keandalan Instrumentasi Pada Unit Central Mechanical Electrical Menggunakan Metode Failure Mode and Effect Analysis (FMEA) (Studi Kasus PT. Telkom Area Network Riau Daratan Pekanbaru)â€, Skripsi, UIN SUSKA RIAU. 2017.

S. Iwan, “FMEA Sebagai Alat Analisa Resiko Moda Kegagalan Pada Magnetic Force Welding Machine ME-27.1â€, Jurnal Batan, No. 13. 2014.

A. Y. Somey, M. L. Pattiapon, B. J. Camerling, “Penerapan Metode Failure Mode and Effect Analysis (FMEA) Pada Mesin Goss Communityâ€, Jurnal I-Tabaos, Vol. 3, No. 2. Juni. 2023.

M. Rizona, Junaidi, F. A. Kurniawan, “Analisa RPN (Risk Priority) Terhadap Keandalan Komponen Mesin Kompresor Double Screw Menggunakan Metode FMEA di Pabrik Semen PT.XYZâ€, Jurnal Buletin Utama Teknik, Vol. 17, No. 1. September. 2017.

H. Firdaus, T. Widianti, “Failure Mode and Effect Analysis (FMEA) Sebagai Tindakan Pencegahan Pada Kegagalan Pengujianâ€, Jurnal LIPI, Vol. 2015, pp. 131-147

A. Rahman, and S. Perdana, “Analisis Perbaikan Kualitas Produk Carton Box di PT XYZ Dengan Metode DMAIC dan FMEAâ€, Jurnal Optimasi Teknik Industri, Vol.. 3. 33-37. 2021.

H. Wibowo, A. Sidiq, and A. Ariyanto, “Penjadwalan Perawatan Komponen Kritis Dengan Pendekatan Reliability Centered Maintenance (Rcm) Pada Perusahaan Karet,†J. Ilm. Tek. Ind., vol. 6, no. 2, pp. 79–87, 2019, doi: 10.24912/jitiuntar.v6i2.4106.

T. J. Wibowo, T. S. Hidayatullah, and A. Nalhadi, “Analisa Perawatan pada Mesin Bubut dengan Pendekatan Reliability Centered Maintenance (RCM),†J. Rekayasa Ind., vol. 3, no. 2, pp. 110–120, 2021, doi: 10.37631/jri.v3i2.485.